National Repository of Grey Literature 38 records found  1 - 10nextend  jump to record: Search took 0.01 seconds. 
Determination of measurement uncertainty of the optical measuring machine using a laser interferometer
Fulová, Silvia ; Jankových, Róbert (referee) ; Šrámek, Jan (advisor)
This final thesis is dealing with stating uncertainty of optical measuring device Micro-Vu Sol 311, which is located at Faculty of mechanical engineering in Brno. Overview of coordinate measuring machines (CMM for short) and analyzed present status of optical CMM is in summation. This part also includes basic metrology concepts and methodology of determination of uncertainty of measuring instrument. Content of following parts of thesis is detailed description of Micro-Vu SOL 311 machine and etalons that were used in determination of enhanced uncertainty of measurement such as gage blocks, laser interferometer and glass scale. Last part of this thesis includes summary of achieved results and recommendations for practice.
Determination of the functional volumes of the reservoir considering input data uncertainties
Paseka, Stanislav ; Doležal, Petr (referee) ; Szolgay,, Ján (referee) ; Marton, Daniel (advisor)
Damaging changes and interventions in the water cycle in our landscape caused mainly in the last century together with uncertainties from climate change are the cause of more frequent occurrences of hydrological extremes. In Hydrology, the most urgent problem is that the values of the long-term mean flows are decreasing in rivers as well as the yield of groundwater sources, but on the other hand, we cannot forget to the problem of extreme floods. In these consequences developing methods and tools to uncertainty analysis of the reservoir yield and of the reservoir flood protection is very important, useful and desired. The main aim was to determine the functional volumes of the reservoir considering input data measurement uncertainties and to quantify them and was explained how uncertainty took into account in results. The active storage capacity was determined from the historical series of monthly flows that were affected by uncertainties, next were applied on water evaporation, seepage losses of the dam and morphological volume-area curves. The simulation-optimization reservoir model was developed and temporal reliability as reservoir yield performance measures was applied. This model will extend the existing UNCE_RESERVOIR software. The flood capacity was determined from random flood wave variations were obtained by repeatedly generating uncertainty on the flood hydrograph. Software was developed based on the modified Klemes method, which was able to transform flood waves. The measurement uncertainties of data inputs were created using Monte Carlo method in both softwares. By connecting two softwares, the functional volumes of the reservoir under conditions of measurement uncertainties were complexly determined. The case study was applied to the real water reservoir, in the Morava River Basin. The result will be whether the dam is resistant to the current conditions, or the optimal design of the functional volumes of reservoir under conditions uncertainties.
Calibration management system of measuring machine (CMM)
Lysý, Zbyněk ; Pernikář, Jiří (referee) ; Koška, Petr (advisor)
This diploma thesis with title of „Management of Coordinate Measuring Machine Calibration“ aimed to develop detailed analysis of uncertainties when deploying 3D coordinate measuring machine MicroVu Excel in practice. The analysis was supported by an example of measuring uncertainty calculation. This thesis also discusses the integration of automatic assessment of uncertainties into programming equipment; and creation of methodical calibration process for this kind of machine.
The influence inclination of supply pipe to the Q/H characteristic of measuring flume PARS P3
Naiser, Dominik ; Žoužela, Michal (referee) ; Zubík, Pavel (advisor)
This bachelor thesis deals with the influence of the inlet pipe on the Q / H characteristic of the measuring flume PARS P3. Measurements of Q / H characteristics were performed under different inclination of the inlet pipe and the measuring flume. Subsequently, these measurements were processed and the corrections and uncertainties of the measurements were determined from the results.
The uncertainty of the coefficient of multiport averaging probe
Maňák, Jan ; Havlíková, Marie (referee) ; Šedivá, Soňa (advisor)
The bachelors thesis is engaged with problem of measurement uncertainty especially for indirect measurement. This issue is shown here on determination uncertainties measurement of coefficient multiport averaging probe Annubar 485 and modified MQS probe.
Expressing uncertainty of accurate lenght measurement II
Šrámek, Jan ; Pernikář, Jiří (referee) ; Koška, Petr (advisor)
This diploma thesis is supposed to inform readers interested in the distance measurements uncertainty on practical issues connected with the solving of these troubles when utilising a frequently used calibration method - the Tesa NPL measure instrument. This measuring was implemented by the Czech Metrologic Institute, where the author works; therefore he could take advantage of his rich experience as well as experience of his superiors and colleagues. The author regards the national metrological institute (CMI) as a sufficient guarantee for the hereinafter presented materials, both regarding the professional qualification and from the perspective of formal rightness of this thesis.
Calibration of pressure gauges
Schwarz, Jakub ; Zuth, Daniel (referee) ; Vdoleček, František (advisor)
This diploma thesis is dealing with pressure measurement. It describes instruments dedicated to purpose - pressure gauges. Basic of correct pressure measurement is knowledge of behaviour of used pressure gauge. This knowledge is acquired by calibration. With calibration is associated also analysis of errors and uncertainty of measurement and creation of calibration list. Calibration takes place on model workspace pressure measuring in laboratory.
The hydraulic modelling research of specific shutter intended for determination of water flow in circular profiles with free surface
Heřmanová, Lenka ; Šafář, Robert (referee) ; Žoužela, Michal (advisor)
The main outcome of this Thesis is a set of Q / h characteristic that was obtained extensive hydraulic model research measuring plate designed for the determination of water flow in circular profiles. The final Q / h characteristic are functions of angle and vertical cut remoteness of the top slot from the bottom of the measurement aperture. Part of the output is an overview of the expected values of uncertainties of measurement in practical use in a specific aperture in sewers and evaluation of impacts involved in determining the overall uncertainty of the flow. The performed hydraulic modeling research is therefore possible to determine Q / h and characteristics for circular sections of larger diameter and to determine their uncertainties when using specific plate. For the design and shape measuring plate of the profile with larger average output is part of a supplement for quick design of specific screens.
The Optimal Accuracy of Measurement Assurance in Accordance with Metrological Confirmation
Frank, Petr ; Kocman, Karel (referee) ; Nenadál, Jaroslav (referee) ; Hruška, Karel (advisor)
This thesis deals with the evaluation of accuracy of measurement and achieving the required accuracy level. This includes global analysis of the uncertainty evaluation, the calibration interval design and the creation of confirmation system. Basis of this work is in identification of all possible problems, which may occur during evaluation of accuracy and achieving the required accuracy level. The analysis is followed by suggested solutions for identified problems. It means namely the selection of probability distribution in case of uncertainty type A, evaluation of degrees of freedom in case of uncertainty type B, nonlinear correlation of input values, evaluation of coverage factor, the choice of method for calibration interval design and the procedure for meeting all metrological confirmation requirements. The last part of the thesis is practical measurement and result evaluation in the field of surge protection devices. This chapter demonstrates conclusions from the syntactical part.
Uncertainties of Accurate Length Measurement
Šrámek, Jan ; Brno), Václav Duchoň (ČMI (referee) ; Vdoleček, František (advisor)
This diploma thesis is supposed to inform readers interested in the distance measurements un-certainty on practical issues connected with the solving of these troubles when utilising a frequently used calibration method - the SIP distance meter. This measuring was implemented by the Czech Metrologic Institute, where the author works; therefore he could take advantage of his rich experience as well as experience of his superiors and colleagues. The author regards the national metrological institute (ČMI) as a sufficient guarantee for the hereinafter presented materials, both regarding the professional qualification and from the perspective of formal rightness of this thesis.

National Repository of Grey Literature : 38 records found   1 - 10nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.